Isotek EVO3 PREMIER POWER CABLE

Isotek



OVERVIEW

Our most affordable mains cable, the EVO3 Premier was inspired by discussions with high-end electronics companies, many of whom produce audio equipment that retails for tens of thousands of pounds and yet is bundled with poor quality power cords that significantly constrain performance. 

This led us to produce a high-quality alternative that respects standard geometric principles, but where every single element is carefully considered, implemented and manufactured to the highest possible standard. There are many brands offering high- quality power cables but these are often very expensive, and also impractical because of their inflexibility and weight. Our goal was to attain similar levels of performance from a more practical cable at a fraction of the price.

The EVO3 Premier not only delivers excellent performance, it also represents outstanding value-for-money. No compromise has been made in relation to the quality of parts and materials used in its construction.

DESIGN

EVO3 Premier

CONSTRUCTION: The conductors are in a parallel construction with a slight rotational twist. This established technique remains the first line of defence against RFI and EMI rejection.

A) Conductors: Silver plated 99.9999% OFC conductors offer an exceptional level of purity with enhanced conductivity. They are less likely to fracture (compared to solid core) or degrade over time. Silver is an excellent conductor and when combined with a high purity copper provides impressive electrical properties.

B) Dielectric: Teflon FEP (Fluorinated Ethylene Propylene) dielectric (insulation) is chemically inert and has a very low dielectric constant over a wide frequency range. FEP possesses a very high degree of stress crack resistance and a low coefficient of friction making it an exceptional dielectric. FEP is the first choice for safety in both temperature and electrical insulation.

C) Filler: Cotton filler has been used to give the cable internal strength and reduce microphony. Cotton also possesses excellent dielectric properties, the best of a solid material.

D) Wrap: A paper wrap is used to secure the construction prior to the application of a flexible PVC jacket. The addition of the paper and cotton form a buffer with the PVC so as to maintain exceptional dielectric properties.

E) Jacket: PVC is used as the outer jacket to give a high degree of flexibility and mechanical strength.

TERMINATION: Premier cable is terminated using IsoTek’s bespoke Audiophile grade moulded connectors of solid OFC with 24ct gold plated conductors. These offer the highest quality performance and are less prone to tarnish.

SPECIFICATIONS

EVO3 Premier

IsoTek Premier uses high quality materials with intelligent construction to deliver a power cable of outstanding performance and mechanical integrity, which will not degrade over time or break your bank balance. 

Cable Length 1.5m standard (no custom length)
Outer Diameter 10mm
Outer Jacket High flexibility PVC
Barrier/Wrap Paper wrap
Filler Cotton
Insulation/Dielectric  Fluorinated Ethylene Propylene (FEP)
Conductors 3 x 2sqmm
Material Silver-plated 99.9999% Oxygen Free Copper 

Capacitance Power Rating Propagation

16 Amp

Unique Termination

Terminated with bespoke audiophile-grade connectors with 24ct gold-plated OFC conductor pins

Suitability

Suitable for CD players, preamps, tuners, power amps, Blu-ray players, music servers, TVs, soundbars and more! 

Related Items


ABOUT THIS WEBSITE

This website is owned and operated by VAF Research (ABN 55 109 262 964) under the domain name vaf.com.au (VAF Website). The information, graphics, text and other materials (Content) on the VAF Website is governed by these Terms of Use and the Privacy Policy available at http://vaf.com.au/privacy/. By using this Website you agree to be bound by these Terms of Use. In addition to the Terms of Use contained in this document, other terms of use or conditions may apply to products and services offered via this Website, as separately notified to you. 

COPYRIGHT AND TRADEMARKS

Copyright in the Content on the VAF Website is owned or licensed by VAF Research. Except where necessary for and incidental to viewing the Content on the VAF Website via your web browser, or as permitted under the Copyright Act 1968 or other applicable laws, no Content on the VAF Website may be reproduced, stored in an electronic or other retrieval system, adapted, uploaded to a third party location, framed, performed in public or transmitted in any form by any process whatsoever without our specific written consent. 

LINKS TO OTHER WEBSITES

The VAF Website may contain links to websites which are owned and operated by third parties independent of us (Third Party Websites). We do not sponsor, endorse or approve of the operators of Third Party Websites or the information, graphics and material which may be found at Third Party Websites (Third Party Material). Subject to any applicable law which cannot be excluded, we make no warranties or representations:

We are not authorising the reproduction of Third Party Material by linking material on this Website to Third Party Material. All offers to sell and statements relating to goods and services available on Third Party Websites are the responsibility of and given by the Third Party Website operators. Insofar as such offers and statements are made on the VAF Website, such offers and statements are made by us on behalf of the Third Party Website operators. We expressly disclaim acting in any other respect on behalf of Third Party Website operators. 

ASSESSMENT TOOLS AND OTHER FEATURES

LIMITATION OF LIABILITY

INDEMNITY

You indemnify us in respect of any liability incurred by us for any loss or damage, howsoever caused, suffered by us as a result of your breach of these VAF Website Terms of Use, or your use of the VAF Website. 

ACCEPTANCE AND CHANGES TO TERMS OF USE

You acknowledge and accept that your use of the VAF Website indicates your acceptance of these Terms of Use and the Privacy Policy. These are the current Terms of Use. They replace any other terms of use for the VAF Website published on the VAF Website to date. VAF Research may at any time vary the Terms of Use by publishing the varied Terms of Use on the VAF Website. VAF Research is under no obligation to specifically notify you of any variation to these Terms of Use. You accept that by doing this, VAF Research has provided you with sufficient notice of the variation. By your use of the VAF Website after any variation, you are taken to have accepted the new Terms of Use. 

GENERAL

The law applicable to VAF Research and the VAF Website and to disputes arising out of VAF Research and the VAF Website is the law of the State of Victoria, Australia. Should any clause or part thereof of these Terms of Use be found to be void, unenforceable or invalid, then it is severed from this agreement, leaving the remainder in full force and effect, provided that the severance has not altered the basic nature of this agreement. 

LINKING TO VAF.COM.AU

We encourage linking to the VAF website. Please contact VAF Research if you would like to link to any part of the VAF Website.